| Customization: | Available |
|---|---|
| After-sales Service: | Yes |
| Warranty: | 5 Years |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency

| Model | SUN-5K-G05P1-EU-AM2 |
| PV String Input Data | |
| Max. PV Input Power (kW) | 7.5 |
| Max. PV Input Voltage (V) | 550 |
| Start-up Voltage (V) | 80 |
| MPPT Voltage Range (V) | 70-500 |
| Rated PV Input Voltage (V) | 360 |
| Max. Operating PV Input Current (A) | 18+18 |
| Max. Input Short Circuit Current (A) | 27+27 |
| No. of MPP Trackers/No. of Strings MPP Tracker | 2/1+1 |
| AC Output Side | |
| Rated AC Output Active Power (kW) | 5 |
| Max. AC Output Apparent Power (kVA) | 5.5 |
| Rated AC Output Current (A) | 22.8/21.8 |
| Max. AC Output Current (A) | 25/24 |
| Rated Output Voltage/Range (V) | 220/230 0.85Un-1.1Un |
| Grid Connection Form | L/N/PE |
| Rated Output Grid Frequency/Range(Hz) | 50/45-55, 60/55-65 |
| Power Factor Adjustment Range | 0.8 leading to 0.8 lagging |
| Total Current Harmonic Distortion THDi | <3% |
| DC Injection Current | <0.5%ln |
| Efficiency | |
| Max. Efficiency | 97.5% |
| Euro Efficiency | 97.0% |
| MPPT Efficiency | >99% |
| Equipment Protection | |
| DC Polarity Reverse Connection Protection | Yes |
| AC Output Overcurrent Protection | Yes |
| AC Output Overvoltage Protection | Yes |
| AC Output Short Circuit Protection | Yes |
| Thermal Protection | Yes |
| DC Terminal Insulation Impedance Monitoring | Yes |
| DC Component Monitoring | Yes |
| Ground Fault Current Monitoring | Yes |
| Arc Fault Circuit Interrupter (AFCI) | Optional |
| Power Network Monitoring | Yes |
| Island Protection Monitoring | Yes |
| Earth Fault Detection | Yes |
| Overvoltage Load Drop Protection | Yes |
| Residual Current (RCD) Detection | Yes |
| Surge Protection Level | TYPE II(DC), TYPE II(AC) |
| Interface | |
| Communication Interface | RS485/RS232 |
| Monitor Mode | GPRS/WIFI/Bluetooth/4G/LAN(optional) |
| General Data | |
| Operating Temperature Range (°C) | -25 to +60ºC, >45ºC Derating |
| Permissible Ambient Humidity | 0-100% |
| Permissible Altitude (m) | 3000m |
| Noise (dB) | ≤35 |
| Ingress Protection(IP) Rating | IP 65 |
| Inverter Topology | Non-Isolated |
| Over Voltage Category | OVC II(DC), OVC III(AC) |
| Cabinet Size (WxHxD mm) | 305×280×180 (Excluding Connectors and Brackets) |
| Weight (kg) | 7.7 |
| Warranty | 5 Years |
| Type of Cooling | Natural Cooling |
| Grid Regulation | IEC 61727, IEC 62116, EN 50549, NRS 097, RD 140, UNE 217002, G98, G99 |
| Safety EMC/Standard | IEC/EN 61000-6-1/2/3/4, IEC/EN 62109-1, IEC/EN 62109-2 |