Model | SUN-10K-G06P3-EU-AM2-P1 |
PV String Input Data | |
Max. PV Input Power (kW) | 15 |
Max. PV Input Voltage (V) | 1100 |
Start-up Voltage (V) | 140 |
MPPT Voltage Range (V) | 120-1000 |
Rated PV Input Voltage (V) | 600 |
Max. Operating PV Input Current (A) | 20+20 |
Max. Input Short Circuit Current (A) | 30+30 |
No. of MPP Trackers/No. of Strings MPP Tracker | 2/1+1 |
AC Output Side | |
Rated AC Output Active Power (kW) | 10 |
Max. AC Output Apparent Power (kVA) | 11 |
Rated AC Output Current (A) | 15.2/14.5 |
Max. AC Output Current (A) | 16.7/16 |
Rated Output Voltage/Range (V) | 220/380V, 230/400V 0.85Un-1.1Un |
Grid Connection Form | 3L/N/PE |
Rated Output Grid Frequency/Range(Hz) | 50/45-55, 60/55-65 |
Power Factor Adjustment Range | 0.8 leading to 0.8 lagging |
Total Current Harmonic Distortion THDi | <3% |
DC Injection Current | <0.5%ln |
Efficiency | |
Max. Efficiency | 98.3% |
Euro Efficiency | 97.8% |
MPPT Efficiency | >99% |
Equipment Protection | |
DC Polarity Reverse Connection Protection | Yes |
AC Output Overcurrent Protection | Yes |
AC Output Overvoltage Protectio | Yes |
AC Output Short Circuit Protection | Yes |
Thermal Protection | Yes |
DC Terminal Insulation Impedance Monitoring | Yes |
DC Component Monitoring | Yes |
Ground Fault Current Monitoring | Yes |
Arc Fault Circuit Interrupter (AFCI) | Optional |
Power Network Monitoring | Yes |
Island Protection Monitoring | Yes |
Earth Fault Detection | Yes |
Overvoltage Load Drop Protection | Yes |
Residual Current (RCD) Detection | Yes |
Surge Protection Level | TYPE II(DC), TYPE II(AC) |
Interface | |
Communication Interface | RS485/RS232 |
Monitor Mode | GPRS/WIFI/Bluetooth/4G/LAN(optional) |
General Data | |
Operating Temperature Range (°C) | -25 to +60ºC, >45ºC Derating |
Permissible Ambient Humidity | 0-100% |
Permissible Altitude (m) | 4000m |
Noise (dB) | <45 |
Ingress Protection(IP) Rating | IP 65 |
Inverter Topology | Non-Isolated |
Over Voltage Category | OVC II(DC), OVC III(AC) |
Cabinet Size (WxHxD mm) | 283×463×178 (Excluding Connectors and Brackets) |
Weight (kg) | 11 |
Warranty | 5 Years |
Type of Cooling | Natural Cooling |
Grid Regulation | IEC 61727, IEC 62116, CEI 0-21, EN 50549, NRS 097, RD 140, UNE 217002, OVE-Richtlinie R25, G98, G99, VDE-AR-N 4105 |
Safety EMC/Standard | IEC/EN 61000-6-1/2/3/4, IEC/EN 62109-1, IEC/EN 62109-2 |